• :  
BM ENG
  • Home
  • Service
  • International Standard
  • FAQ
  • Publish
  • signin
  •  Cart ()
Search Malaysian Standard (MS)
 Advanced Search Search




STERILIZATION OF HEALTH CARE PRODUCTS - RADIATION - PART 1: REQUIREMENTS FOR DEVELOPMENT, VALIDATION AND ROUTINE CONTROL OF A STERILIZATION PROCESS FOR MEDICAL DEVICES (ISO 11137-1:2006, IDT)
MS ISO 11137-1:2010 (CONFIRMED:2020)
Status : Original
Format : PDF

This Malaysian Standard specifies requirements for the development, validation and routine control of a radiation sterilization process for medical devices. 
NOTE: Although the scope of this st ....Read more andard is limited to medical devices, it specifies requirements and provides guidance that may be applicable to other products and equipment.

This standard covers radiation processes employing irradiators using:
a) the radionuclide 60 CO or 137 CS;
b) a beam from an electron generator; or
c) a beam from an X-ray generator.

This Malaysian Standard does not specify requirements for development, validation and routine control of a process for inactivating the causative agents of spongiform encephalopathies such as scrapie, bovine spongiform encephalopathy and Creutzfeldt-Jakob disease. Specific recommendations have been produced in particular countries for the processing of materials potentially contaminated with these agents.

This standard does not:
- detail specified requirements for des
Close

RM 75.00

Document will be sent via email



 Add To Cart

Sterilization of health care products - Radiation - Part 3: Guidance on dosimetric aspects (ISO 11137-3:2006, IDT)
MS ISO 11137-3:2011
Status : Original
Format : PDF

This Malaysian Standard gives guidance on the requirements relating to dosimetry. Dosimetry procedures related to the development, validation and routine control of a radiation sterilization process a ....Read more re described. Close

RM 30.00

Document will be sent via email



 Add To Cart

STERILIZATION OF HEALTH CARE PRODUCTS - ETHYLENE OXIDE - PART 1: REQUIREMENTS FOR DEVELOPMENT, VALIDATION AND ROUTINE CONTROL OF A STERILIZATION PROCESS FOR MEDICAL DEVICES (ISO 11135-1:2007, IDT)
MS ISO 11135-1:2010
Status : Original
Format : PDF

This Malaysian Standard specifies requirements for the development, validation and routine control of an ethylene oxide sterilization process for medical devices. Sterilization processes validated and ....Read more controlled in accordance with the requirements of this standard are not assumed to be effective in inactivating the causative agents of spongiform encephalopathies such as scrapie, bovine spongiform encephalopathy and Creutzfeld Jacob disease. Specific recommendations have been produced in particular countries for the processing of materials potentially contaminated with these agents. Close

RM 75.00

Document will be sent via email



 Add To Cart

RECREATIONAL DIVING SERVICES - REQUIREMENTS FOR INTRODUCTORY TRAINING PROGRAMMES TO SCUBA DIVING (ISO 11121:2009, IDT)
MS ISO 11121:2011
Status : Original
Format : PDF

This Malaysian Standard specifies minimum requirements for training organisations that offer introductory scuba experience training programmes to non- divers. This standard appiles to programmes that ....Read more include participants being taken into an open water environment. It does not apply to programmes that are exclusively conducted in a confined water environment (e.g. swinmming pools). Close

RM 30.00

Document will be sent via email



 Add To Cart

Gas cylinders - Valve protection caps and valve guards - Design, construction and tests (ISO 11117:2008, IDT)
MS ISO 11117:2012
Status : Original
Format : PDF

This Malaysian Standard specifies the requirements for valve protection caps and guards for cylinders. 
This Malaysian Standard defines test for checking the mechanical strength and physical pr ....Read more operties of the valve protection cap or valve guard.

This Malaysian Standard applies to protection devices for valves used on cylinders for liquefied, dissolved or compressed gases. This International Standard excludes protection devices for cylinders with a water capacity of 5 l or less and cylinders whereby the protection device is fixed by means of lugs welded or brazed to the cylinder, or is welded or brazed directly to the cylinder. This International Standard does not cover valve protection for breathing apparatus cylinders.

This Malaysian Standard does not specify all the requirements that may be necessary to enable the valve protection device to be used for lifting the cylinder.
Close

RM 30.00

Document will be sent via email



 Add To Cart

TRANSPORTABLE GAS CYLINDERS - COMPATIBILITY OF CYLINDER AND VALVE MATERIALS WITH GAS CONTENTS - PART 2: NON-METALLIC MATERIALS (ISO 11114-2:2000, IDT)
MS ISO 11114-2:2008
Status : Original
Format : PDF

This Malaysian Standard gives guidance in the selection and evaluation of compatibility between non-metallic materials for gas cylinders and valves and the cylinders' gas contents. This Malaysian Stan ....Read more dard also covers bundles, tubes and pressure drums. This standard may be helpful for composite and laminated materials. Only the influence of the gas in changing the material and mechanical properties is considered (for example chemical reaction or change in physical state). The basic mechanical properties of the materials required for design purposes are normally available from the materials supplier and are not considered in this standard. The compatibility data given are related to single component gases but can be used to some extent for gas mixtures. Ceramics, glasses, and adhesives are not covered by this standard. Aspects such as quality of delivered gas are not considered. Close

RM 45.00

Document will be sent via email



 Add To Cart

TRANSPORTABLE GAS CYLINDERS - COMPATIBILITY OF CYLINDER AND VALVE MATERIALS WITH GAS CONTENTS - PART 1: METALLIC MATERIALS (ISO 11114-1:1997, IDT)
MS ISO 11114-1:2008
Status : Original
Format : PDF

This Malaysian Standard gives guidance in the selection and evaluation of compatibility between metallic gas cylinder and valve materials and the gas content.The compatibility data given is related to ....Read more single component gases.Seamless and welded gas cylinders used to contain compressed, liquefied and dissolvedgases, are considered. 
NOTE: In this Standard the term “cylinder” refers to transportable pressure receptacles, whichalso include tubes and pressure drums.
Aspects such as quality of delivered product are not considered.
Close

RM 75.00

Document will be sent via email



 Add To Cart

RECREATIONAL DIVING SERVICES - REQUIREMENTS FOR TRAINING PROGRAMMES ON ENRICHED AIR NITROX (EAN) DIVING (ISO 11107:2009, IDT)
MS ISO 11107:2011
Status : Original
Format : PDF

This Malaysian Standard specifies the level of competence required of a scuba diver in order to be awarded an enriched air nitrox (EAN) diver certification by a training organisation. This standard do ....Read more es not specifies the conditions under which training is to be provided, which supplement the general requirements for recreational diving services specified in ISO 24803. Close

RM 15.00

Document will be sent via email



 Add To Cart

Linear calibration using reference materials (ISO 11095:1996, IDT)
MS ISO 11095:2001 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard: 
a) outlines the general principles needed to calibrate a measurement system and to maintain that “calibrated” measurement system in a state of statistical control; ....Read more

b) provides a basic method

- for estimating a linear calibration function under either one of two assumptions relating to the variability of the measurements,

- for checking the assumption of linearity of the calibration function and the assumptions on the variability of the measurements, and

- for estimating the value of a new unknown quantity by transforming the measured values obtained on that quantity with the calibration function;

c) provides a control method for extended use of a calibration function

- for detecting when the calibration function needs to be updated, and

- for estimating the uncertainty of the measured values after transformation with the calibration
function;

d) provides two alternatives to the basic method under special conditions;

e) illustrates the basic m
Close

RM 60.00

Document will be sent via email



 Add To Cart

Paper and board - Testing of cores - Part 5: Determination of characteristics of concentric rotation (First revision) (ISO 11093-5:2009, COR. 1:2010, IDT)
MS ISO 11093-5:2012
Status : 1st Revision
Format : PDF

This Malaysian Standard specifies a method for determining the characteristics of concentric rotation of cylindrical board cores.

RM 15.00

Document will be sent via email



 Add To Cart

  • ‹
  • 1
  • 2
  • ...
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • ...
  • 548
  • 549
  • ›
©2020 All rights reserved
Department of Standards Malaysia (STANDARDS MALAYSIA). Best viewed on latest browser.