• :  
BM ENG
  • Home
  • Service
  • International Standard
  • FAQ
  • Publish
  • signin
  •  Cart ()
Search Malaysian Standard (MS)
 Advanced Search Search




STATIONARY SOURCE EMISSIONS - DETERMINATION OF GAS AND PARTICLE-PHASE POLYCYCLIC AROMATIC HYDROCARBONS - PART 2: SAMPLE PREPARATION, CLEAN-UP AND DETERMINATION (ISO 11338-2:2003, IDT)
MS ISO 11338-2:2011
Status : Original
Format : PDF

This Malaysian Standard specifies procedures for sample preparation, clean-up and analysis for the determination of gas and particle-phase polycyclic aromatic hydrocarbons (PAH) in stack and waste gas ....Read more es. 
The analytical methods are capable of detecting sub-microgram concentrations of PAH per cubic metre of sample, depending on the type of PAH and the flue gas volume sampled.
Close

RM 45.00

Document will be sent via email



 Add To Cart

Nanotechnologies - Characterization of volatile components in single-wall carbon nanotube samples using evolved gas analysis/gas chromatograph-mass spectrometry (ISO/TS 11251:2010, IDT)
MS ISO/TS 11251:2012
Status : Original
Format : PDF

This Malaysian Standard specifies a method for the characterization of volatile components in single-wall carbon nanotubes (SWCNTs) samples using evolved gas analysis/gas chromatograph mass spectromet ....Read more ry (EGA/GCMS). Close

RM 30.00

Document will be sent via email



 Add To Cart

ERGONOMIC – EVALUATION OF STATIC WORKING POSTURES (ISO 11226:2000, IDT)
MS ISO 11226:2003 (CONFIRMED:2019)
Status : Original
Format : PDF

This Malaysian Standard establishes ergonomic recommendations for different work tasks. This standard provides information to those involved in design, or redesign, of work, jobs and products who are ....Read more familiar with the basic concepts of ergonomics in genral, and working postures in particular. 
It specifies recommended limits for static working postures without any or only with minimal external force exertion,while taking into account body angles and time aspects

It is designed to provide guidance on the assessment of several task variables, allowing the heallth risks for the working population to be evaluated

It applies to the adult working population. The recommendation will give reasonable protection for nearly all healthy adults. The recommendations concerning health risk and protection are mainly based on experimental studies regarding the musculoskeletal load,discomfort/pain, and endurance/fatique related to static working postures
Close

RM 45.00

Document will be sent via email



 Add To Cart

AIR QUALITY - DETERMINATION OF THE UNCERTAINTY OF THE TIME AVERAGE OF AIR QUALITY MEASUREMENTS (ISO 11222:2002, IDT)
MS ISO 11222:2009
Status : Original
Format : PDF

This Malaysian Standard provides a method for the quantification of the uncertainty of a time average of a set of air quality data obtained at a specified location over a defined averaging time period ....Read more . The method is applicable to air quality data obtained by continuous or intermittent monitoring by means of a specified measuring system. The uncertainty of the time average depends on both the uncertainty of the measurement results and the uncertainty due to incomplete time coverage of the data set. 
This Malaysian Standard is only applicable if:
a) the set of air quality data used to calculate the time average is representative of the temporal structure of the measurand over the defined time period,
b) appropriate information on the uncertainty of the measurement results is available, and
c) the measurement results have all been obtained at the same location.

This Malaysian Standard implements recommendations of the Guide to the expression of uncertainty in measurement (GUM).
Close

RM 45.00

Document will be sent via email



 Add To Cart

DETERMINATION OF PLATINUM IN PLATINUM JEWELLERY ALLOYS - GRAVIMETRIC METOD AFTER PRECIPITATION OF DIAMMONIUM HEXACHLOROPLATINATE
MS ISO 11210:1997 (CONFIRMED:2003)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies a gravimetric method for the determination of platinum in platinum jewellery alloys, preferably within the range of fineness stated in ISO 9202. 
These alloys ....Read more may contain Palladium, iridium, rhodium, topper, Cobalt, gold, ruthenium, gallium, chromium,
indium and less than 5 % tungsten. Some modifications are indicated where Palladium, iridium, rhodium,
gold or ruthenium are present.
Close

RM 15.00

Document will be sent via email



 Add To Cart

MEDICAL SUPPLY UNITS (ISO 11197:2004, IDT)
MS ISO 11197:2006
Status : Original
Format : PDF

This Malaysian Standard applies to medical supply units. Medical supply unit - fixed equipment intended to supply electric power and/or medical gases and/or liquids and anaesthetic gas scavenging syst ....Read more ems to medical areas of a health-care facility Close

RM 75.00

Document will be sent via email



 Add To Cart

Gas mixers for medical use - Standalone gas mixers (ISO 11195:1995, IDT)
MS ISO 11195:2008 (CONFIRMED:2013)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard gives requirements for the performance and safety of stand-alone gas mixers intended for medical use and intended for connection to a medical gas supply system. 
This st ....Read more andard does not apply to:
a) blocks of flowmeters with separate controls for the flow of each gas;
b) gas mixers which mix Oxygen with ambient air;
c) gas mixers which depend on other medical devices for functions required by this Standard.
Close

RM 30.00

Document will be sent via email



 Add To Cart

THERMOPLASTICS PIPES – DETERMINATION OF RESISTANCE TO EXTERNAL BLOWS – STAIRCASE METHOD (ISO 11173:1994, IDT)
MS ISO 11173 : 2002 (CONFIRMED:2019)
Status : Original
Format : PDF

This Malaysian Standard specifies a method for determining the resistance to external blows of thermoplastic pipes of circular Cross-section; it is called the staircase method. This method is applicab ....Read more le to isolated batches of pipe to be tested at 0°C. 
NOTE 1 If testing below 0°C is necessary, the temperature of - 20°C is recommended.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Information technology - Coding of moving pictures and associated audio for digital storage media at up to about 1,5 Mbit/s - Part 4: Compliance testing (ISO/IEC 11172-4:1995, IDT)
MS ISO/IEC 11172-4:2003 (CONFIRMED:2015)
Status : Original
Format : PDF

This Malaysian Standard specifies how tests can be designed to verify whether bitstreams and decoders meet requirements specified in parts 1, 2 and 3 of MS ISO/IEC 11172. In this standard, encoders ar ....Read more e not addressed specifically. An encoder is entitled to be an MS ISO/IEC 11172 encoder if it generates bitstreams compliant with the syntactic and semantic bitstream requirements specified in parts 1, 2 and 3 of MS ISO/IEC 11172. 
Characteristics of coded bitstreams and decoders are defined for parts 1, 2 and 3 of MS ISO/IEC 11172. The characteristics of a bitstream define the subset of the standard that is exploited in the bitstream. Examples are the applied values or range of the picture size and bit rate parameters. Decoder characteristics define the properties and capabilities of the applied decoding process. An example of a property is the applied arithmetic accuracy. The capabilities of a decoder specify which coded bitstreams the decoder can decode and reconstruct, by defining the s
Close

RM 75.00

Document will be sent via email



 Add To Cart

Information technology - Coding of moving pictures and associated audio for digital storage media at up to about 1,5 Mbit/s - Part 3: Audio (ISO/IEC 11172-3:1993, IDT)
MS ISO/IEC 11172-3:2003 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies the coded representation of high quality audio for storage media and the method for decoding of high quality audio signals. The input of the encoder and the output of ....Read more the decoder are compatible with existing PCM standards such as standard Compact Disc and Digital Audio Tape. 
This standard is intended for application to digital storage media providing a total continuous transfer rate of about 1,5 Mbit/s for both audio and video bitstreams, such as CD, DAT and magnetic hard disc. The storage media may either be connected directly to the decoder, or via other menas such as communication lines and the multiplexed stream defined in MS ISO/IEC 11172-1. This standard is intended for sampling rates of 32 kHz, 44,1 kHz, and 48 kHz.
Close

RM 240.00

Document will be sent via email



 Add To Cart

  • ‹
  • 1
  • 2
  • ...
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • ...
  • 548
  • 549
  • ›
©2020 All rights reserved
Department of Standards Malaysia (STANDARDS MALAYSIA). Best viewed on latest browser.