• :  
BM ENG
  • Home
  • Service
  • International Standard
  • FAQ
  • Publish
  • signin
  •  Cart ()
Search Malaysian Standard (MS)
 Advanced Search Search




Road vehicles - Recyclability and recoverability - Calculation method (ISO 22628:2002, IDT)
MS ISO 22628:2009 (CONFIRMED:2016)
Status : Original
Format : PDF

This Malaysian Standard specifies a method for calculating the recyclability rate and the recoverability rate of a new road vehicle, each expressed as a percentage by mass (mass fraction in percent) o ....Read more f the road vehicle, which can potentially be

- recycled, reused or both (recyclability rate)
- or recovered, reused or both (recoverability rate).

The calculation is performed by the vehicle manufacturer when a new vehicle is put on the market.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Clothing for protection against infectious agents - Test method for resistance to dry microbial penetration (ISO 22612:2005, IDT)
MS ISO 22612:2011 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard provides a means for assessing the resistance to penetration through barrier materials of bacteria-carrying particles.

NOTE: Due to its complexity, this Malaysian ....Read more Standard cannot be considered as a useful method for routine quality controL but may suit the needs when a material is assessed for compliance with the requirements of current regulations such as EU Directive 93/42/EEC. Close

RM 30.00

Document will be sent via email



 Add To Cart

Surgical drapes, gowns and clean air suits, used as medical devices, for patients, clinical staff and equipment - Test method to determine the resistance to wet bacterial penetration (ISO 22610:2006, IDT)
MS ISO 22610:2011 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies a test method, with associated test apparatus (see Annex A), which is used to determine the resistance of a material to the penetration of bacteria, carried by a liqu ....Read more id, when subjected to mechanical rubbing. Close

RM 30.00

Document will be sent via email



 Add To Cart

Clothing for protection against infectious agents - Medical face masks - Test method for resistance against penetration by synthetic blood (fixed volume, horizontally projected) (ISO 22609:2004, IDT)
MS ISO 22609:2011 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard describes a laboratory test method for measuring the resistance of medical face masks to penetration by a splash of synthetic blood.

This Malaysian Standard prima ....Read more rily addresses the performance of materials or certain material constructions used in medical face masks. This test method does not address the performance of the medical face mask's design, construction, interfaces or other factors which may affect the overall protection offered by the medical face mask and its operation (such as filtration efficiency and pressure drop).

This test method does not evaluate the performance of medical face masks as a protection against contamination via airborne exposure pathways or in the prevention of the penetration of aerosolized body fluids deposited on the medical face mask.
Close

RM 45.00

Document will be sent via email



 Add To Cart

Plastics - Vinyl chloride homopolymer and copolymer resins - Particle size determination by mechanical sieving (ISO 22498 :2005, IDT)
MS ISO 22498:2012
Status : Original
Format : PDF

This Malaysian Standard specifies a method for the determination of the size distribution of particles of vinyl chloride homopolymer and copolymer resins by measuring the amounts retained on a selecti ....Read more on of sieves having meshes of various aperture sizes.

The results can be expressed either in terms of the amount retained on the individual sieves or as the mean particle size for the whole test sample.

The method is not recommended for use with sieves having mesh sizes smaller than 0.038 mm.
Close

RM 15.00

Document will be sent via email



 Add To Cart

Medical devices utilizing animal tissues and their derivatives - Part 3: Validation of the elimination and/or inactivation of viruses and transmissible spongiform encephalopathy (TSE) agents (ISO 22442-3:2007, IDT)
MS ISO 22442-3:2010 (CONFIRMED:2015)
Status : Withdrawn
Format : PDF

This Malaysian Standard specifies requirements for the validation of the elimination and/or inactivation of viruses and TSE agents during the manufacture of medical devices (excluding in vitro diagnos ....Read more tic medical devices) utilizing animal tissue or products derived from animal tissue, which are non-viable or have been rendered non-viable. It applies where required by the risk management process as described in MS ISO 22442-1. It does not cover other transmissible and non-transmissible agents.

This standard does not consider the effect of any method of elimination and/or inactivation on the suitability of the medical device for its intended use.
Close

NOT FOR SALE

Please contact us if you are interested to purchase for reference.




Medical devices utilising animal tissues and their derivatives - Part 4: Principles for elimination and/or inactivation of transmissible spongiform encephalopathy (TSE) agents and validation assays for those processes
MS 22442-4:2013
Status : Withdrawn
Format : PDF

This Malaysian Standard offers suggestions for designing and conducting validation assays to help determine if processes used in the manufacture of medical devices derived from non-viable animal tissu ....Read more es might serve to reduce the risk of iatrogenic transmission of transmissible spongiform encephalopathies (TSEs).

The TSE-removal methods used to process animal tissues should also reduce the risk of transmitting TSE infections via non-viable tissues of human origin; this standard does not address this issue. Some current information on human tissues and TSEs is presented which may be applied by analogy to other animal tissues.

This standard is intended to clarify standards included in the MS ISO 22442 series, as well as in MS ISO 14160. This standard builds upon the specific discussion in MS ISO 22442-3 relative to TSE agents and attempts to summarize the current state of the art in the arena of TSE agent elimination.
Close

NOT FOR SALE

Please contact us if you are interested to purchase for reference.




Transportable gas cylinders - Inspection and maintenance of cylinder valves (ISO 22434:2006, IDT)
MS ISO 22434:2012
Status : Original
Format : PDF

This Malaysian Standard specifies the requirements for the inspection and maintenance of cylinder valves with intergrated pressure regulators (VIPR).

This Malaysian Standard may be appli ....Read more ed to cylinder valves at time of periodic inspection of gas cylinders, bundles, drums and trailers, and at any other time. Close

RM 15.00

Document will be sent via email



 Add To Cart

FINE CERAMICS (ADVANCED CERAMICS, ADVANCED TECHNICAL CERAMICS) - TEST METHOD FOR TENSILE CREEP OF MONOLITHIC CERAMICS (ISO 22215:2006, IDT)
MS ISO 22215:2006
Status : Original
Format : PDF

This Malaysian Standard specifies the test method for determining the tensile-creep strain and creep rupture time under uniaxial constant force of monolithic fine ceramics and whisker or particulate-r ....Read more einforced ceramic composites at high temperatures.This test method may be used for material development, material comparison, quality assurance, characterization and design data generation. Close

RM 30.00

Document will be sent via email



 Add To Cart

FINE CERAMICS (ADVANCED CERAMICS, ADVANCED TECHNICAL CERAMICS) – TEST METHOD FOR CYCLIC BENDING FATIGUE OF MONOLITHIC CERAMICS AT ROOM TEMPERATURE (ISO 22214:2006, IDT)
MS ISO 22214:2007
Status : Original
Format : PDF

This Malaysian Standard specifies a test method for four-point cyclic bending fatigue of fine ceramics that are carried out in the air at room temperature. This test may be used as a pass/fail test fo ....Read more r material qualification purposes, or for determination of the overall fatigue behaviour at several different stress levels. Close

RM 30.00

Document will be sent via email



 Add To Cart

  • ‹
  • 1
  • 2
  • ...
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • ...
  • 548
  • 549
  • ›
©2020 All rights reserved
Department of Standards Malaysia (STANDARDS MALAYSIA). Best viewed on latest browser.