MEDICAL DEVICES FOR CONSERVING OXYGEN AND OXYGEN MIXTURES - PARTICULAR REQUIREMENTS (ISO 18779:2005, IDT)
MS ISO 18779:2008
Status : Original
Format : PDF

This Malaysian Standard specifies requirements for the safety and essential performance of portable devices that supply the flow of oxygen or oxygen mixtures during therapy (e.g. long term oxygen ther ....Read more apy, analgesia). This Malaysian Standard covers two types of conserving devices: conserving devices intended for continuous use and those not intended for continuous use. This Malaysian Standard covers active devices only, e.g. pneumatically or electrically controlled devices, and does not cover devices such as reservoir cannulas. This Malaysian Standard also includes conserving devices which are part of a system, e.g. pressure regulators, oxygen concentrators or liquid oxygen vessels. Close

RM 60.00

Document will be sent via email



 Add To Cart

RESPIRATORY EQUIPMENT - INFANT MONITORS - PARTICULAR REQUIREMENTS (ISO 18778:2005, IDT)
MS ISO 18778:2008
Status : Original
Format : PDF

This Malaysian Standard specifies requirements for the safety and essential performance of monitors used to detect apparent life-threatening events1) in sleeping or resting children under three years ....Read more of age. This Malaysian Standard applies to devices used in home care applications. These monitors are generally used without continual professional supervision.

This Malaysian Standard also applies to the accessories, e.g. probes and cables necessary to apply the monitor to the patient.

This Malaysian Standard does not apply to monitors intended for use in health care facilities/institutions. The requirements of this Malaysian Standard, which replace or modify the requirements of IEC 60601-1:1988 and its Amendments 1 (1991) and 2 (1995), are intended to take precedence over the corresponding general requirements.
Close

RM 60.00

Document will be sent via email



 Add To Cart

Transportable liquid oxygen systems for medical use - Particular requirements (ISO 18777:2005, IDT)
MS ISO 18777:2008 (CONFIRMED:2013)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies requirements for the safety and essential performance of transportable liquid oxygen systems which are used as a supply source for oxygen therapy. These devices usual ....Read more ly consist of a portable unit to be carried by or with the patient whilst in use and the vessel used to refill the portable unit. These devices are mostly used in home care applications and in health care facilities/institutions. These devices are often used without professional supervision. Close

RM 60.00

Document will be sent via email



 Add To Cart

FINE CERAMICS (ADVANCED CERAMICS, ADVANCED TECHNICAL CERAMICS) - DETERMINATION OF SPECIFIC SURFACE AREA OF CERAMIC POWDERS BY GAS ADSORPTION USING THE BET METHOD (ISO 18757:2003, IDT)
MS ISO 18757:2008
Status : Original
Format : PDF

This Malaysian Standard provides guidelines for the determination of the total specific external and internalsurface area of disperse or porous (pore diameter greater than 2 nm) fine ceramic materials ....Read more by measuring the amount of physically adsorbed gas according to the method of Brunauer, Emmet and Teller (BET method). General guidelines of the method are described in ISO 9277. This Malaysian Standard only focuses on specific details relevant to fine ceramic materials. It should further be noted that the BET method cannot be applied to type I isotherms (microporous materials or chemisorption behaviour) or when the solid absorbs the measuring gas. Close

RM 30.00

Document will be sent via email



 Add To Cart

FINE CERAMICS (ADVANCED CERAMICS, ADVANCED TECHNICAL CERAMICS) - DETERMINATION OF THERMAL DIFFUSIVITY OF MONOLITHIC CERAMICS BY LASER FLASH METHOD (ISO 18755:2005, IDT)
MS ISO 18755:2006
Status : Original
Format : PDF

This Malaysian Standard specifies the test method for the determination of thermal diffusivity from room temperature to 1700 K by laser flash method for homogeneous ceramics with porosity less than 10 ....Read more %. Close

RM 60.00

Document will be sent via email



 Add To Cart

FINE CERAMICS (ADVANCED CERAMICS, ADVANCED TECHNICAL CERAMICS) - DETERMINATION OF ABSOLUTE DENSITY OF CERAMIC POWDERS BY PYKNOMETER (ISO 18753:2004, IDT)
MS ISO 18753:2005
Status : Original
Format : PDF

This Malaysian Standard specifies a method for determining the particle density of fine ceramic powders using liquid pyknometry.

RM 30.00

Document will be sent via email



 Add To Cart

FINE CERAMICS (ADVANCED CERAMICS, ADVANCED TECHNICAL CERAMICS) – DETERMINATION OF ABSOLUTE DENSITY OF CERAMIC POWDERS BY PYKNOMETER (ISO 18753:2004, IDT)
MS ISO 18753:2007
Status : Original
Format : PDF

This Malaysian Standard specifies a method for determining the particle density of fine ceramic powders using liquid pyknometry.

RM 30.00

Document will be sent via email



 Add To Cart

RUBBER, VULCANIZED OR THERMOPLASTIC - HARDNESS TESTING - INTRODUCTION AND GUIDE (ISO 18517:2005, IDT)
MS ISO 18517:2007
Status : Withdrawn
Format : PDF

This Malaysian Standard provides guidance on the determination of the hardness of vulcanized and thermoplastic rubbers.

It is intended to provide an understanding of the significance of ....Read more hardness as a material property and to assist in the selection of an appropriate test method. Close

NOT FOR SALE

Please contact us if you are interested to purchase for reference.




Sterilization of health care products - Biological and chemical indicators - Test equipment (ISO 18472:2006, IDT)
MS ISO 18472:2011
Status : Original
Format : PDF

This Malaysian Standard specifies the requirements for test equipment to be used to test chemical and biological indicators for steam, ethylene oxide, dry heat and vaporized hydrogen peroxide processe ....Read more s for conformity to the requirements given in MS ISO 11140-1 for chemical indicators, or the requirements given in the MS ISO 11138 series for biological indicators. This standard also provides informative methods useful in characterizing the performance of biological and chemical indicators for intended use and for routine quality control testing. Close

RM 60.00

Document will be sent via email



 Add To Cart

OPHTHALMIC OPTICS - CONTACT LENSES - PART 3: MEASUREMENT METHODS (ISO 18369-3:2006, IDT)
MS ISO 18369-3:2009
Status : Original
Format : PDF

This Malaysian Standard specifies the methods for measuring the physical and optical properties of contact lenses specified in MS ISO 18369-2, i.e. radius of curvature, back vertex power, diameter, th ....Read more ickness, inspection of edges, inclusions and surface imperfections, and determination of spectral and luminous transmittances. This Malaysian Standard also specifies the equilibrating solution, standard saline solution, for testing of contact lenses. Close

RM 75.00