• :  
BM ENG
  • Subscription
  • MS Catalogue
  • MS Pack
  • Purchase History
  • Cart
  • Hi
    !
    • My Profile
    • Portal
    • Log Out

Modal title

Widget settings form goes here

Search Malaysian Standard (MS)
 Advanced Search Search


Prophylactic dams - Requirements and test methods (ISO 29942:2011, IDT)
MS ISO 29942:2013
Status : Withdrawn
Format : PDF

This Malaysian Standard specifies the minimum requirements and test methods for prophylactic dams used to assist in the prevention of sexually transmitted infections.

NOT FOR SALE

Please contact us if you are interested to purchase for reference.




Information technology - Office equipment - Method for measuring digital copying productivity of a single one-sided original (ISO/IEC 29183:2010, IDT)
MS ISO/IEC 29183:2012
Status : Original
Format : PDF

This Malaysian Standard specifies a method for measuring productivity of digital copying devices and multifunctional devices with various copying modes and a single one-sided original. It is applicabl ....Read more e to digital copying devices and multifunctional devices. It is intended to be used for black-and-white and colour digital copying devices and multifunctional devices of any underlying marking technology. This Malaysian Standard includes instructions for the creation of test charts, test setup procedure, test procedure, and the reporting requirements for the digital copying productivity measurements. Close

RM 45.00

Document will be sent via email



 Add To Cart

Software engineering - Lifecycle profiles for Very Small Entities (VSEs) - Part 2-1: Framework and taxonomy (ISO/IEC 29110-2-1:2015, IDT)
MS ISO/IEC 29110-2-1:2018
Status : Original
Format : PDF

This Malaysian Standard specifies the major concepts for software and systems engineering profiles for VSEs, and defines the terms common to the set of documents associated with VSE profiles. The sta ....Read more ndard establishes the logic behind the definition and application of profiles. It specifies the elements common to all standardised profiles, structure, conformance and assessment. Close

RM 60.00

Document will be sent via email



 Add To Cart

Information technology - Office equipment - Colour photo test pages for measurement of ink cartridge yield for colour photo printing (ISO/IEC 29103:2011, IDT)
MS ISO/IEC 29103:2012
Status : Original
Format : PDF

This Malaysian Standard defines colour test pages for the measurement of consumable yield when printing photographs. These pages can be used for any printing technology including multi-function device ....Read more s that have a digital printing path, i.e. an all-in-one inkjet machine that has digital printing capabilities. Close

RM 15.00

Document will be sent via email



 Add To Cart

Safety of machinery - Evaluation of the emission of airborne hazardous substances - Part 8: Room method for the measurement of the pollutant concentration parameter (ISO 29042-8:2011, IDT)
MS ISO 29042-8:2012 (CONFIRMED:2019)
Status : Original
Format : PDF

This Malaysian Standard specifies a room method for the measurement of the pollutant concentration parameter of a given airborne hazardous substance from machines, located in a test room and operating ....Read more the machines under defined conditions. This method is applicable only to machines with a local exhaust ventilation with an air flow rate >=500 m3/h and machines without recirculated air. Measurement of the pollutant concentration parameter of a machine can serve for the: a) evaluation of the performance of a machine;
b) evaluation of the improvement of the machine;
c) comparison of machines within different groups of machines with the same intended use (such groups being defined by the function and materials processed)
d) ranking of machines from the same group according to their pollutant concentration parameters;
e) Determination of the state of the art of a machine with respect to its pollutant concentration parameter
Close

RM 15.00

Document will be sent via email



 Add To Cart

Safety of machinery - Evaluation of the emission of airborne hazardous substances - Part 9: Decontamination index (ISO 29042-9:2011, IDT)
MS ISO 29042-9:2012 (CONFIRMED:2019)
Status : Original
Format : PDF

This Malaysian Standard specifies a method for the measurement of the decontamination index of pollutant control systems, e. g. capture devices including local exhaust ventilation, water spray systems ....Read more and, when appropriate, separation equipment installed on a machine. This method uses the real pollutant and can be operated in room or field environments. Measurement of the decontamination index of a pollutant control system can serve for the: a) evaluation of the performance of a pollutant control system of a machine;
b) evaluation of the improvement of a pollutant control system;
c) comparison of pollutant control systems for machines of similar design;
d) ranking of pollutant control systems according to their decontamination efficiency;
e) determination of the air flow rate in the case of an exhaust system to achieve a given level;
f) determination of the state of the art of pollutant control systems for machines with respect to the decontamination efficiency
Close

RM 30.00

Document will be sent via email



 Add To Cart

Double sampling plans by attributes with minimal sample sizes, indexed by producer’s risk quality (PRQ) and consumer’s risk quality (CRQ) (ISO 28801:2011, IDT) (Published by STANDARDS MALAYSIA in 2012)
MS ISO 28801:2011
Status : Withdrawn
Format : PDF

This Malaysian Standard provides double sampling plans by attributes for the acceptance inspection of lots of discrete items. The plans are indexed by the producer's risk quality (PRQ) and the consume ....Read more r's risk quality (CRQ). A lot is accepted if there are no nonconforming items (nonconformities) in the first random sample, and rejected if it contains two or more nonconforming items (nonconformities). If precisely one nonconforming item is found in the first sample, a second random sample is drawn; the lot is then accepted if the second sample contains no nonconforming items (nonconformities) and rejected otherwise. 
The objective of this standard is to provide procedures that enable lot disposition to be determined quickly and economically if quality is particularly good or bad. For intermediate quality, a second sample is drawn in order to be able to discriminate more reliably between acceptable and unacceptable lots. The plans are particular suitable for isolated lots or for short ser
Close

NOT FOR SALE

Please contact us if you are interested to purchase for reference.




Fine ceramics (advanced ceramics, advanced technical ceramics) - Test method for cyclic bending fatigue of porous ceramics at room temperature (ISO 28704:2011, IDT)
MS ISO 28704:2012 (CONFIRMED 2018)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard spedifies a test method for determining the cyclic four-point bending fatigue of porous ceramics in air at room temperature.

RM 30.00

Document will be sent via email



 Add To Cart

Fine ceramics (advanced ceramics, advanced technical ceramics) - Test method for thermal-shock resistance of porous ceramics (ISO 28703:2011, IDT)
MS ISO 28703:2012 (CONFIRMED 2018)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies a test method for determining the thermal-shock resistance of porous ceramics by water quenching using the bending strength. This test method can be used for selectio ....Read more n of materials during design. Close

RM 15.00

Document will be sent via email



 Add To Cart

FINE CERAMICS (ADVANCED CERAMICS, ADVANCED TECHNICAL CERAMICS) - TEST METHOD FOR ANTIBACTERIAL ACTIVITY OF SEMICONDUCTING PHOTOCATALYTIC MATERIALS (ISO 27447:2009, IDT)
MS ISO 27447:2011
Status : Original
Format : PDF

This Malaysian Standard specifies a test method for the determination of the antibacterial activity of materials that contain a photocatalyst or have photocatalytic films on the surface, by measuring ....Read more the enumeration of bacteria under irradiation of ultraviolet light. 
This Malaysian Standard is intended for use with different kinds of semiconducting photocatalytic materials used in construction materials, in flat sheet, board, plate shape or textiles that are the basic forms of materials for various applications. It does not include powder, granular or porous photocatalytic materials. 
The values expressed in this International Standard are in accordance with the International System of Units (SI).
Close

RM 45.00

Document will be sent via email



 Add To Cart

  • ‹
  • 1
  • 2
  • ...
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • ...
  • 548
  • 549
  • ›