Primary batteries - Part 4: Safety of lithium batteries (First revision) (IEC 60086-4:2014, IDT)
MS IEC 60086-4:2017
Status : 1st Revision
Format : PDF

This Malaysian Standard specifies tests and requirements for primary lithium batteries to ensure their safe operation under intended use and reasonably foreseeable misuse.

NOTE. Primary ....Read more lithium batteries that are standardized in IEC 60086-2 are expected to meet all applicable requirements herein. It is understood that consideration of this part of IEC 60086 might also be given to measuring and/or ensuring the safety of non-standardised primary lithium batteries. In either case, no claim or warranty is made that compliance or non-compliance with this standard will fulfil or not fulfil any of the user's particular purposes or needs Close

RM 60.00

Document will be sent via email



 Add To Cart

Primary batteries - Part 1: General (Fourth revision) (IEC 60086-1:2015, IDT)
MS IEC 60086-1:2017
Status : 1st Revision
Format : PDF

This Malaysian Standard is intended to standardise primary batteries with respect to dimensions, nomenclature, terminal configurations, markings, test methods, typical performance, safety and environm ....Read more ental aspects.

As a primary battery classification tool, electrochemical systems are also standardized with respect to system letter, electrodes, electrolyte, nominal and maximum open circuit voltage.

The objective of this standard is to benefit primary battery users, device designers and battery manufacturers by ensuring that batteries from different manufacturers are interchangeable according to standard form, fit and function. Furthermore, to ensure compliance with the above, this part specifies standard test methods for testing primary cells and batteries.
Close

RM 75.00

Document will be sent via email



 Add To Cart

Electrical insulation - Thermal evaluation and designation (IEC 60085:2007, IDT)
MS IEC 60085:2013
Status : Original
Format : PDF

This Malaysian Standard establishes the criteria for evaluating the thermal endurance of either electrical insulating materials (EIM) or electrical insulation systems (EIS) and to establish the proced ....Read more ure for assigning thermal classes. Close

RM 15.00

Document will be sent via email



 Add To Cart

Double-capped fluorescent lamps - Performance specifications (IEC 60081:2003, IDT)
MS IEC 60081:2003 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies the performance requirements for double-capped fluorescent lamps for general lighting service.

The requirements of this standard relate only to type tes ....Read more ting. Conditions of compliance, including methods of statistical assessment, are under consideration. Close

RM 270.00

Document will be sent via email



 Add To Cart

Explosive atmospheres - Part 6: Equipment protection by oil immersion ā€œOā€ (First revision) (IEC 60079-6:2007, IDT)
MS IEC 60079-6:2007 (CONFIRMED:2013)
Status : 1st Revision
Format : PDF

This Malaysian Standard IEC 60079 specifies the requirements for the construction and testing of oil-immersed electrical equipment, oil-immersed parts of electrical equipment and Ex components in the ....Read more type of protection oil immersion "o", intended for use in explosive gas atmospheres. Close

RM 30.00

Document will be sent via email



 Add To Cart

Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" (Second revision) (IEC 60079-11:2011, IDT)
MS IEC 60079-11:2012
Status : 2nd Revision
Format : PDF

This Malaysian Standard specifies the construction and testing of intrinsically safe apparatus intended for use in an explosive atmosphere and for associated apparatus, which is intended for connectio ....Read more n to intrinsically safe circuits which enter such atmospheres. This type of protection is applicable to electrical equipment in which the electrical circuits themselves are incapable of causing an explosion in the surrounding explosive atmosphere. Close

RM 210.00

Document will be sent via email



 Add To Cart

Explosive atmospheres - Part 0: Equipment - General requirements (Second revision) (IEC 60079-0:2011, IDT)
MS IEC 60079-0:2012
Status : 2nd Revision
Format : PDF

This Malaysian Standard specifies the general requirements for construction, testing and marking of electrical equipment and Ex components intended for use in explosive atmospheres.

RM 165.00

Document will be sent via email



 Add To Cart

Explosive atmospheres - Part 17: Electrical installations inspection and maintenance (Second revision) (IEC 60079-17:2013, IDT)
MS IEC 60079-17:2017
Status : 2nd Revision
Format : PDF

This Malaysian Standard specifies factors directly related to the inspection and maintenance of electrical installations within hazardous areas only, where the hazard may be caused by flammable gases, ....Read more vapours, mists, dusts, fibres or flyings. It does not apply to underground mining areas, areas where a risk can arise due to the presence of hybrid mixtures, dusts of explosives that do not require atmospheric oxygen for combustion, and pyrophoric substances. Close

RM 60.00

Document will be sent via email



 Add To Cart

Explosive atmospheres - Part 2: Equipment protection by pressurized enclosure ā€œPā€ (First revision) (IEC 60079-2:2007, IDT)
MS IEC 60079-2:2007 (CONFIRMED:2013)
Status : 1st Revision
Format : PDF

This Malaysian Standard specific requirements for the construction and testing of electrical apparatus with pressurized enclosures, of type of protection "p", intended for use in explosive gas atmosph ....Read more eres. It specifies requirements for pressurized enclosures containing a limited release of a flammable substance. Close

RM 90.00

Document will be sent via email



 Add To Cart

EXPLOSIVE ATMOSPHERES - PART 18: EQUIPMENT PROTECTION BY ENCAPSULATION "M" (SECOND REVISION) (IEC 60079-18:2009, IDT)
MS IEC 60079-18:2010
Status : 2nd Revision
Format : PDF

This Malaysian Standard specifies the requirements for the construction, testing and marking of electrical equipment, parts of electrical equipment and Ex components with the type of protection encaps ....Read more ulation "m" intended for use in explosive gas atmospheres or explosive dust atmospheres. Close

RM 60.00